Right-click on the KEPServerEX icon on your desktop and from the menu select OPC UA Configuration.Host: localhost, if the Kepware server is hosted on your own machine otherwise use the actual IP address of the machine Name: Kepware, the name you specify here will appear under Devices folder on the Quick Client page in the Gateway. On the New OPC Server Connection page, leave all the default values and type in the following fields:.Choose OPC-UA as the connection type and click Next.The Add OPC Server Connection Step 1: Choose Type page is displayed. Find the orange arrow and click on Create new OPC Server Connection….The OPC Server Connection page is displayed showing the OPC-UA servers you Ignition is connected to. In the Configure section of the Gateway, go to OPC Connections > Servers.Go to the OPC Connections > Quick Client in the Configure section of the Gateway, under the Kepware > Channel1 > Device1 folder you will see the Tag folders.Also ensure your firewall is not blocking traffic on the port that KEPServerEX is using to communicate. If Status is still reading something other than Connected, click the OPC Connection Status link at the bottom of the OPC Server Connections page and see if there are any useful messages to help troubleshoot the issue. Troubleshooting: If Status does not read Connected, click the edit link next to the server connection, scroll down to the bottom of the connection configuration page, and click Save. Now the OPC Server Connections page shows the Status of Kepware to be Connected. On the OPC UA Configuration Manager window, go to the Trusted Clients tab, click on Ignition OPC-UA Client, click the Trust button, and click Close.

The OPC UA Configuration Manager is will appear. Right-click on the KEPServerEX icon on the desktop KEPServerEx is installed on and from the menu select OPC UA Configuration. The next step is to have KEPServerEX trust the Ignition OPC-UA Client. This is expected because KEPServerEX is denying access to the Ignition OPC-UA Client.
OPC UA CONNECT TO KEPSERVEREX PASSWORD
A Username and Password do not need to be given, and should be left blank.

A list of available Security Policies and Message Security options will appear. Once an endpoint has been entered, click the Discover button. #If KepServer is installed on a different server from Ignition, then the IP address would be used:
OPC UA CONNECT TO KEPSERVEREX DRIVER
Kepware DA Client driver (to connect to OPC DA Clients such as HMIs).Kepware UA Client driver (to connect to OPC UA Servers).Kepware OPC Connectivity Suite (아래 제품 모두 포함) 사용.Kepware OPC DA Client driver 사용 (3rd Party DA-only Server 사용시).Kepware OPC Server 사용 (UA & DA Server 동시 지원).